Model |
HESS3K5 | HESS5K5 |
|
Performance Specifications |
||
|
Phase |
Single Phase | |
|
Battery Capacity |
5.12kWh | |
|
Battery Type |
LiFePO4 | |
|
Nominal Voltage |
51.2V | |
|
Voltage Range |
44.8V-58.4V | |
|
Nominal Capacity |
100Ah | |
|
Standard Charge Current |
20A | |
|
Maximum Charge Current |
50A | |
|
Standard Discharge |
20A | |
|
Maximum Discharge Rate |
100A | |
|
Communication Protocol |
CAN、RS232、RS485 | |
|
Cycle Life |
≥6000cycles | |
|
Design life |
≥10years | |
|
Operating Temperature |
-20°C~65°C | |
|
Storage Temperature |
Within 1month: -20~45°C,1-3months: 0~35°C, 3-12months: 15~25°C | |
|
Inverter mode |
||
|
Output voltage waveform |
Pure sine wave | |
|
Rated Output Power |
3000W | 5000W |
|
Peak power |
6000VA | 10000VA |
|
Loaded motor capability |
2HP | 4HP |
|
Bypass breaker specifications |
30A | 40A |
|
Power factor |
1 | |
|
Rated output voltage |
230Vac | |
|
Output voltage error |
±5% | |
|
Output frequency range |
50Hz ± 0.3Hz/60Hz ± 0.3Hz | |
|
Maximum Efficiency |
>92% | |
|
Overload protection |
(110% < load <125%) ±10%: report error and turn off the output after 5 minutes; (125% < load < 150%) ± 10%: report error and turn off the output after 10 seconds; Load >150% ±10%: report error and turn off the output after 5 seconds; |
|
|
Output short circuit protection |
Circuit breaker | |
|
Bypass breaker specifications |
30A40A | |
|
AC mode |
||
|
Rated input voltage |
220/230Vac | |
|
Input voltage range |
(170Vac~280Vac) ±2%/(90Vac-280Vac)±2% | |
|
Frequency |
50Hz/ 60Hz (Auto detection) | |
|
Frequency Range |
47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz) | |
|
Overload/short circuit protection |
Circuit breaker | |
|
Efficiency |
>95% | |
|
Conversion time (bypass and inverter) |
10ms (typical) | |
|
AC reverse protection |
Available | |
|
Maximum bypass overload current |
30A | |
|
AC charging |
||
|
Maximum charge current |
60A | |
|
Charge voltage range |
40–58Vdc | |
|
Short circuit protection |
Circuit breaker and blown fuse | |
|
Circuit breaker specifications |
30A | |
|
Overcharge protection |
Alarm and turn off charging after 1 minute | |
|
PV charging |
||
|
Maximum PV open circuit voltage |
145Vdc | |
|
PV operating voltage range |
60-145Vdc | |
|
MPPT voltage range |
60-115Vdc | |
|
Battery voltage range |
40-60Vdc | |
|
Maximum input power |
3400W | |
|
PV charging current range (can be set) |
0-60A | |
|
Charging short circuit protection |
Blown fuse | |
|
Wiring protection |
Reverse polarity protection | |
|
Other |
||
|
Unit Dimension |
L380mm* W161.5mm* H1171mm | |
|
Unit Weight |
66kg | 70kg |