Why Can't Charge A LiFePO4 Cell Below 0°C (32°F)?

Sep 05, 2022 Leave a message

When using lithium iron phosphate batteries, there are some situations that need to be consider. For example, do not charge the battery at less than 0 °C (32 °F).

 

Lets check the specifications of the EVE LF280N battery cells.


1

Discharge working temperature: -30°C  ~ 60°C(-22 °F ~ 140 °F)

Charging working temperature: 0°C ~ 60°C(32 °F ~ 140 °F)

 

So why we can not charging LFP battery below 0°C( 32 °F )?


When charging a Lithium battery below 0°C(32°F), it will trigger the lithium plating phenomenon.

 

LiFePO4 51.2V 300Ah 15Kwh Stackable Battery.1


What is lithium plating?


Lithium plating is the formation of metallic lithium around the anode.

 

During the charging process, lithium ions from the cathode are inserted into a compound with a layered structure in the anode. During this process, also known as intercalation, is when lithium plating occurs.

 

Low temperatures slows down the reaction of lithium electrons, which affects the intercalation of lithium ions. It forms lithium metal at this time.

 

When lithium plating reaction occurs, the internal resistance of the battery increases and reduces the rate of chemical metabolism.

 

Further more it causes a permanent reduction of the batterys capacity and will continue to reduce its capacity each time this reaction occurs.

 

The optimum ambient temperature for charging a Lithium battery is 5°C 45°C (41°F 113°F.)

 

LiFePO4 51.2V 600Ah 30Kwh  Stackable Battery.3


How to avoid charging in low temperature?


If you plan to use lithium iron phosphate batteries in places where the temperature may fall below 0 °C (32 °F), you need to take some precautions for low-temperature charging.

 

  • Place the battery pack in a room where the temperature is higher than the outside environment.

  • Using a BMS with a low-temperature cutoff feature.

  • Monitoring the battery pack temperature.


Send Inquiry